Help Center

Threshold - cmaHardwareAlerts

Properties

Nodes to Run On: #DefaultNode

Threshold Conditions

CerFanStatus

Where Clause:

STATUS <> "OK" AND STATUS <> "OTHER" AND STATUS <> EMPTY

Alarm Interval:

Every30 Second(s)

Nodes to Monitor:

#All Telephony Systems\Cisco Emergency Responder\All Nodes

Record:

CERFAN

Message Destinations:

Problem Summary

Event No

0

Message

^srcnode@: Fan state @CERFAN.Status@ for @CERFAN.Id@ on Cisco Emergency Responder @CERFAN.Cluster@

Severity

 Error

Dispatch Manager

Message

^srcnode@: Fan state @CERFAN.Status@ for @CERFAN.Id@ on Cisco Emergency Responder @CERFAN.Cluster@

Severity

 Error

SNMP Trap

Message

^srcnode@: Fan state @CERFAN.Status@ for @CERFAN.Id@ on Cisco Emergency Responder @CERFAN.Cluster@

Severity

 Error

CerPowerSupplyStatus

Where Clause:

STATDESC <> "OK"AND STATDESC <> "OTHER" AND STATDESC <> EMPTY

Alarm Interval:

Every30 Second(s)

Nodes to Monitor:

#All Telephony Systems\Cisco Emergency Responder\All Nodes

Record:

CERPOW

Message Destinations:

Problem Summary

Event No

0

Message

^srcnode@: Power supply state @CERPOW.StatDesc@ for @CERPOW.Id@ on Cisco Emergency Responder @CERPOW.Cluster@

Severity

 Error

SNMP Trap

Message

^srcnode@: Power supply state @CERPOW.StatDesc@ for @CERPOW.Id@ on Cisco Emergency Responder @CERPOW.Cluster@

Severity

 Error

Dispatch Manager

Message

^srcnode@: Power supply state @CERPOW.StatDesc@ for @CERPOW.Id@ on Cisco Emergency Responder @CERPOW.Cluster@

Severity

 Error

CerTemperatureCritical

Where Clause:

TEMP > CTHUPP

Alarm Interval:

Every30 Second(s)

Nodes to Monitor:

#All Telephony Systems\Cisco Emergency Responder\All Nodes

Record:

CERTEMP

Message Destinations:

Problem Summary

Event No

0

Message

^srcnode@: Temperature critical alarm for @CERTEMP.Id@ on Cisco Emergency Responder @CERTEMP.Cluster@, current temperature: @CERTEMP.TEMP@, upper critical temperature threshold: @CERTEMP.CthUpp@

Severity

 Critical

SNMP Trap

Message

^srcnode@: Temperature critical alarm for @CERTEMP.Id@ on Cisco Emergency Responder @CERTEMP.Cluster@, current temperature: @CERTEMP.TEMP@, upper critical temperature threshold: @CERTEMP.CthUpp@

Severity

 Critical

Dispatch Manager

Message

^srcnode@: Temperature critical alarm for @CERTEMP.Id@ on Cisco Emergency Responder @CERTEMP.Cluster@, current temperature: @CERTEMP.TEMP@, upper critical temperature threshold: @CERTEMP.CthUpp@

Severity

 Critical

CerTemperatureError

Where Clause:

CTHLOW <> EMPTY AND CTHUPP <> EMPTY AND TEMP > CTHLOW AND (TEMP < CTHUPP OR TEMP = CTHUPP)

Alarm Interval:

Every30 Second(s)

Nodes to Monitor:

#All Telephony Systems\Cisco Emergency Responder\All Nodes

Record:

CERTEMP

Message Destinations:

Problem Summary

Event No

0

Message

^srcnode@: Temperature error for @CERTEMP.Id@ on Cisco Emergency Responder @CERTEMP.Cluster@, current temperature: @CERTEMP.TEMP@, lower critical temperature threshold: @CERTEMP.CthLow@

Severity

 Error

SNMP Trap

Message

^srcnode@: Temperature error for @CERTEMP.Id@ on Cisco Emergency Responder @CERTEMP.Cluster@, current temperature: @CERTEMP.TEMP@, lower critical temperature threshold: @CERTEMP.CthLow@

Severity

 Error

Dispatch Manager

Message

^srcnode@: Temperature error for @CERTEMP.Id@ on Cisco Emergency Responder @CERTEMP.Cluster@, current temperature: @CERTEMP.TEMP@, lower critical temperature threshold: @CERTEMP.CthLow@

Severity

 Error

CerTemperatureWarning

Where Clause:

NCTHLOW <> EMPTY AND CTHLOW <> EMPTY AND TEMP > NCTHLOW AND (TEMP < CTHLOW OR TEMP=CTHLOW)

Alarm Interval:

Every30 Second(s)

Nodes to Monitor:

#All Telephony Systems\Cisco Emergency Responder\All Nodes

Record:

CERTEMP

Message Destinations:

Problem Summary

Event No

0

Message

^srcnode@: Temperature warning for @CERTEMP.Id@ on Cisco Emergency Responder @CERTEMP.Cluster@, current temperature: @CERTEMP.TEMP@, upper non-critical temperature threshold: @CERTEMP.NcthUpp@

Severity

 Warning

SNMP Trap

Message

^srcnode@: Temperature warning for @CERTEMP.Id@ on Cisco Emergency Responder @CERTEMP.Cluster@, current temperature: @CERTEMP.TEMP@, upper non-critical temperature threshold: @CERTEMP.NcthUpp@

Severity

 Warning

Dispatch Manager

Message

^srcnode@: Temperature warning for @CERTEMP.Id@ on Cisco Emergency Responder @CERTEMP.Cluster@, current temperature: @CERTEMP.TEMP@, upper non-critical temperature threshold: @CERTEMP.NcthUpp@

Severity

 Warning

HP Drive Array Acc Err

Where Clause:

CONDITN <> "ok" AND CONDITN <> EMPTY

Alarm Interval:

Every2 Minute(s)

Nodes to Monitor:

#ALL TELEPHONY SYSTEMS\CISCO CALLMANAGER APPLIANCE\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNITY CONNECTIONS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO CONTACT CENTER EXPRESS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNIFIED PRESENCE\ALL NODES\HP NODES

Record:

CPQIMDAA

Message Destinations:

Dispatch Manager

Message

^srcnode@: Drive Array Accelerator @CPQIMDAA.CTLRINDX@ Condition = @CPQIMDAA.CONDITN@

Severity

 Warning

Problem Summary

Event No

0

Message

^srcnode@: Drive Array Accelerator @CPQIMDAA.CTLRINDX@ Condition = @CPQIMDAA.CONDITN@

Severity

 Warning

SNMP Trap

Message

^srcnode@: Drive Array Accelerator @CPQIMDAA.CTLRINDX@ Condition = @CPQIMDAA.CONDITN@

Severity

 Warning

HP Drive Box Err

Where Clause:

CONDITN <> "ok" AND CONDITN <> "other" AND CONDITN <> EMPTY

Alarm Interval:

Every2 Minute(s)

Nodes to Monitor:

#ALL TELEPHONY SYSTEMS\CISCO CALLMANAGER APPLIANCE\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNITY CONNECTIONS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO CONTACT CENTER EXPRESS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNIFIED PRESENCE\ALL NODES\HP NODES

Record:

CPQIMDBX

Message Destinations:

Dispatch Manager

Message

^srcnode@: Drive Box @CPQIMDBX.MODEL@ (@CPQIMDBX.CTLRINDX@) Condition = @CPQIMDBX.CONDITN@

Severity

 Warning

Problem Summary

Event No

0

Message

^srcnode@: Drive Box @CPQIMDBX.MODEL@ (@CPQIMDBX.CTLRINDX@) Condition = @CPQIMDBX.CONDITN@

Severity

 Warning

SNMP Trap

Message

^srcnode@: Drive Box @CPQIMDBX.MODEL@ (@CPQIMDBX.CTLRINDX@) Condition = @CPQIMDBX.CONDITN@

Severity

 Warning

HP Drv Array Ctl Err

Where Clause:

BRDSTATS <> "ok" and BRDSTATS <> "other" AND BRDSTATS <> EMPTY

Alarm Interval:

Every2 Minute(s)

Nodes to Monitor:

#ALL TELEPHONY SYSTEMS\CISCO CALLMANAGER APPLIANCE\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNITY CONNECTIONS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO CONTACT CENTER EXPRESS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNIFIED PRESENCE\ALL NODES\HP NODES

Record:

CPQIMDAC

Message Destinations:

Dispatch Manager

Message

^srcnode@: Drive Array Controller @CPQIMDAC.MODEL@ (@CPQIMDAC.INDEX@) Status = @CPQIMDAC.BRDSTATS@

Severity

 Warning

Problem Summary

Event No

0

Message

^srcnode@: Drive Array Controller @CPQIMDAC.MODEL@ (@CPQIMDAC.INDEX@) Status = @CPQIMDAC.BRDSTATS@

Severity

 Warning

SNMP Trap

Message

^srcnode@: Drive Array Controller @CPQIMDAC.MODEL@ (@CPQIMDAC.INDEX@) Status = @CPQIMDAC.BRDSTATS@

Severity

 Warning

HP Fan Err

Where Clause:

FANCOND <> "ok" AND FANCOND <> "other" AND FANCOND <> EMPTY

Alarm Interval:

Every2 Minute(s)

Nodes to Monitor:

#ALL TELEPHONY SYSTEMS\CISCO CALLMANAGER APPLIANCE\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNITY CONNECTIONS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO CONTACT CENTER EXPRESS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNIFIED PRESENCE\ALL NODES\HP NODES

Record:

CPQIMFAN

Message Destinations:

Dispatch Manager

Message

^srcnode@: Fan @CPQIMFAN.FANINDEX@ Condition = @CPQIMFAN.FANCOND@

Severity

 Warning

Problem Summary

Event No

0

Message

^srcnode@: Fan @CPQIMFAN.FANINDEX@ Condition = @CPQIMFAN.FANCOND@

Severity

 Warning

SNMP Trap

Message

^srcnode@: Fan @CPQIMFAN.FANINDEX@ Condition = @CPQIMFAN.FANCOND@

Severity

 Warning

HP Logical Drive Err

Where Clause:

CONDITN <> "ok" AND CONDITN <> EMPTY

Alarm Interval:

Every2 Minute(s)

Nodes to Monitor:

#ALL TELEPHONY SYSTEMS\CISCO CALLMANAGER APPLIANCE\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNITY CONNECTIONS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO CONTACT CENTER EXPRESS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNIFIED PRESENCE\ALL NODES\HP NODES

Record:

CPQIMLDV

Message Destinations:

Dispatch Manager

Message

^srcnode@: Logical Drive @CPQIMLDV.INDEX@/@CPQIMLDV.CTLRINDX@ Condition = @CPQIMLDV.CONDITN@

Severity

 Warning

Problem Summary

Event No

0

Message

^srcnode@: Logical Drive @CPQIMLDV.INDEX@/@CPQIMLDV.CTLRINDX@ Condition = @CPQIMLDV.CONDITN@

Severity

 Warning

SNMP Trap

Message

^srcnode@: Logical Drive @CPQIMLDV.INDEX@/@CPQIMLDV.CTLRINDX@ Condition = @CPQIMLDV.CONDITN@

Severity

 Warning

HP Phys Disk Threshold

Where Clause:

THRSPSSD = "true"

Alarm Interval:

Every2 Minute(s)

Nodes to Monitor:

#ALL TELEPHONY SYSTEMS\CISCO CALLMANAGER APPLIANCE\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNITY CONNECTIONS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO CONTACT CENTER EXPRESS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNIFIED PRESENCE\ALL NODES\HP NODES

Record:

CPQIMPDV

Message Destinations:

Dispatch Manager

Message

^srcnode@: Physical Disk @CPQIMPDV.INDEX@ Threshold Passed = @CPQIMPDV.THRSPSSD@

Severity

 Warning

Problem Summary

Event No

0

Message

^srcnode@: Physical Disk @CPQIMPDV.INDEX@ Threshold Passed = @CPQIMPDV.THRSPSSD@

Severity

 Warning

SNMP Trap

Message

^srcnode@: Physical Disk @CPQIMPDV.INDEX@ Threshold Passed = @CPQIMPDV.THRSPSSD@

Severity

 Warning

HP Power Supply Err

Where Clause:

CONDITN <> "ok" AND CONDITN <> "other" AND CONDITN <> EMPTY

Alarm Interval:

Every2 Minute(s)

Nodes to Monitor:

#ALL TELEPHONY SYSTEMS\CISCO CALLMANAGER APPLIANCE\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNITY CONNECTIONS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO CONTACT CENTER EXPRESS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNIFIED PRESENCE\ALL NODES\HP NODES

Record:

CPQIMPWR

Message Destinations:

Dispatch Manager

Message

^srcnode@: Power Supply @CPQIMPWR.CHASSIS@ Condition = @CPQIMPWR.CONDITN@

Severity

 Warning

Problem Summary

Event No

0

Message

^srcnode@: Power Supply @CPQIMPWR.CHASSIS@ Condition = @CPQIMPWR.CONDITN@

Severity

 Warning

SNMP Trap

Message

^srcnode@: Power Supply @CPQIMPWR.CHASSIS@ Condition = @CPQIMPWR.CONDITN@

Severity

 Warning

HP Tape Drive Clean Req

Where Clause:

CLEANREQ = "true"

Alarm Interval:

Every2 Minute(s)

Nodes to Monitor:

#ALL TELEPHONY SYSTEMS\CISCO CALLMANAGER APPLIANCE\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNITY CONNECTIONS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO CONTACT CENTER EXPRESS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNIFIED PRESENCE\ALL NODES\HP NODES

Record:

CPQIMTPD

Message Destinations:

Dispatch Manager

Message

^srcnode@: Clean is required for tape drive @CPQIMTPD.DRVNAME@

Severity

 Warning

Problem Summary

Event No

0

Message

^srcnode@: Clean is required for tape drive @CPQIMTPD.DRVNAME@

Severity

 Warning

SNMP Trap

Message

^srcnode@: Clean is required for tape drive @CPQIMTPD.DRVNAME@

Severity

 Warning

HP Tape Drive Err

Where Clause:

CONDITON <> "ok" AND CONDITON <> "other" AND CONDITON <> EMPTY

Alarm Interval:

Every2 Minute(s)

Nodes to Monitor:

#ALL TELEPHONY SYSTEMS\CISCO CALLMANAGER APPLIANCE\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNITY CONNECTIONS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO CONTACT CENTER EXPRESS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNIFIED PRESENCE\ALL NODES\HP NODES

Record:

CPQIMTPD

Message Destinations:

Dispatch Manager

Message

^srcnode@: Tape Drive @CPQIMTPD.DRVNAME@ Condition = @CPQIMTPD.CONDITON@

Severity

 Warning

Problem Summary

Event No

0

Message

^srcnode@: Tape Drive @CPQIMTPD.DRVNAME@ Condition = @CPQIMTPD.CONDITON@

Severity

 Warning

SNMP Trap

Message

^srcnode@: Tape Drive @CPQIMTPD.DRVNAME@ Condition = @CPQIMTPD.CONDITON@

Severity

 Warning

HP Temp Sensor Threshold

Where Clause:

STATE <> "ok" AND STATE <> EMPTY

Alarm Interval:

Every2 Minute(s)

Nodes to Monitor:

#ALL TELEPHONY SYSTEMS\CISCO CALLMANAGER APPLIANCE\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNITY CONNECTIONS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO CONTACT CENTER EXPRESS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNIFIED PRESENCE\ALL NODES\HP NODES

Record:

CPQIMTMP

Message Destinations:

Dispatch Manager

Message

^srcnode@: Temp Sensor @CPQIMTMP.SENSORID@, Temp : @CPQIMTMP.TEMPFAHR@ Fh ( @CPQIMTMP.TEMPCELS@ C) - Check Status

Severity

 Warning

Problem Summary

Event No

0

Message

^srcnode@: Temp Sensor @CPQIMTMP.SENSORID@, Temp : @CPQIMTMP.TEMPFAHR@ Fh ( @CPQIMTMP.TEMPCELS@ C) - Check Status

Severity

 Warning

SNMP Trap

Message

^srcnode@: Temp Sensor @CPQIMTMP.SENSORID@, Temp : @CPQIMTMP.TEMPFAHR@ Fh ( @CPQIMTMP.TEMPCELS@ C) - Check Status

Severity

 Warning

HP UPS Line Status

Where Clause:

(LINESTAT <> "ok" AND LINESTAT <> EMPTY ) OR ESTBATLF < 2

Alarm Interval:

Every2 Minute(s)

Nodes to Monitor:

#ALL TELEPHONY SYSTEMS\CISCO CALLMANAGER APPLIANCE\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNITY CONNECTIONS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO CONTACT CENTER EXPRESS\ALL NODES\HP NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNIFIED PRESENCE\ALL NODES\HP NODES

Record:

CPQIMUPS

Message Destinations:

Dispatch Manager

Message

^srcnode@: UPS Line Status = @CPQIMUPS.LINESTAT@, Est Battery Life = @CPQIMUPS.ESTBATLF@ Hrs

Severity

 Warning

Problem Summary

Event No

0

Message

^srcnode@: UPS Line Status = @CPQIMUPS.LINESTAT@, Est Battery Life = @CPQIMUPS.ESTBATLF@ Hrs

Severity

 Warning

SNMP Trap

Message

^srcnode@: UPS Line Status = @CPQIMUPS.LINESTAT@, Est Battery Life = @CPQIMUPS.ESTBATLF@ Hrs

Severity

 Warning

IBM Fan Sensor Err

Where Clause:

STATUS <> EMPTY AND STATUS <> "OK"

Alarm Interval:

Every2 Minute(s)

Nodes to Monitor:

#ALL TELEPHONY SYSTEMS\CISCO UNITY CONNECTIONS\ALL NODES\IBM NODES,
#ALL TELEPHONY SYSTEMS\CISCO CALLMANAGER APPLIANCE\ALL NODES\IBM NODES,
#ALL TELEPHONY SYSTEMS\CISCO CONTACT CENTER EXPRESS\ALL NODES\IBM NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNIFIED PRESENCE\ALL NODES\IBM NODES

Record:

Message Destinations:

Problem Summary

Event No

0

Message

^srcnode@: Fan: @IBMTACH.TACHNAME@ status: @IBMTACH.STATUS@. Speed = @IBMTACH.FANSPEED@ RPM.

Severity

 Warning

Dispatch Manager

Message

^srcnode@: Fan: @IBMTACH.TACHNAME@ status: @IBMTACH.STATUS@. Speed = @IBMTACH.FANSPEED@ RPM.

Severity

 Warning

SNMP Trap

Message

^srcnode@: Fan: @IBMTACH.TACHNAME@ status: @IBMTACH.STATUS@. Speed = @IBMTACH.FANSPEED@ RPM.

Severity

 Warning

IBM Temp Sensor Err

Where Clause:

STATUS <> EMPTY AND STATUS <> "OK"

Alarm Interval:

Every2 Minute(s)

Nodes to Monitor:

#ALL TELEPHONY SYSTEMS\CISCO CALLMANAGER APPLIANCE\ALL NODES\IBM NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNITY CONNECTIONS\ALL NODES\IBM NODES,
#ALL TELEPHONY SYSTEMS\CISCO CONTACT CENTER EXPRESS\ALL NODES\IBM NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNIFIED PRESENCE\ALL NODES\IBM NODES

Record:

Message Destinations:

Problem Summary

Event No

0

Message

^srcnode@: Temperature sensor: @IBMTEMP.TSENNAME@ status: @IBMTEMP.STATUS@. Temperature = @IBMTEMP.TEMPFAHR@ F (@IBMTEMP.TEMPCELS@ C)

Severity

 Warning

Dispatch Manager

Message

^srcnode@: Temperature sensor: @IBMTEMP.TSENNAME@ status: @IBMTEMP.STATUS@. Temperature = @IBMTEMP.TEMPFAHR@ F (@IBMTEMP.TEMPCELS@ C)

Severity

 Warning

SNMP Trap

Message

^srcnode@: Temperature sensor: @IBMTEMP.TSENNAME@ status: @IBMTEMP.STATUS@. Temperature = @IBMTEMP.TEMPFAHR@ F (@IBMTEMP.TEMPCELS@ C)

Severity

 Warning

IBM Voltage Sensor Err

Where Clause:

STATUS <> EMPTY AND STATUS <> "OK"

Alarm Interval:

Every2 Minute(s)

Nodes to Monitor:

#ALL TELEPHONY SYSTEMS\CISCO CALLMANAGER APPLIANCE\ALL NODES\IBM NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNITY CONNECTIONS\ALL NODES\IBM NODES,
#ALL TELEPHONY SYSTEMS\CISCO CONTACT CENTER EXPRESS\ALL NODES\IBM NODES,
#ALL TELEPHONY SYSTEMS\CISCO UNIFIED PRESENCE\ALL NODES\IBM NODES

Record:

Message Destinations:

Problem Summary

Event No

0

Message

^srcnode@: Voltage sensor: @IBMVOLT.VSENNAME@ status: @IBMVOLT.STATUS@. Voltage = @IBMVOLT.VOLTAGE@ mV.

Severity

 Warning

Dispatch Manager

Message

^srcnode@: Voltage sensor: @IBMVOLT.VSENNAME@ status: @IBMVOLT.STATUS@. Voltage = @IBMVOLT.VOLTAGE@ mV.

Severity

 Warning

SNMP Trap

Message

^srcnode@: Voltage sensor: @IBMVOLT.VSENNAME@ status: @IBMVOLT.STATUS@. Voltage = @IBMVOLT.VOLTAGE@ mV.

Severity

 Warning

Provide feedback on this article